OVHCloud Public Cloud Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
auth.cloud.ovh.net - Keystone API v2.0
Scheduled Maintenance Report for Public Cloud
Completed
The maintenance is planned on June 23, 2020 at 12:00 UTC.

We are going to disable keystone (OpenStack Identity Service) API v2.0 (https://auth.cloud.ovh.net/v2.0/)

An email was sent to warn users: https://ovh.to/d8o5FtL

API v2.0 has been deprecated for years and API v3 (https://auth.cloud.ovh.net/v3/) should be used.

Openrc file for version 3 can be downloaded at https://api.ovh.com/console/#/cloud/project/%7BserviceName%7D/user/%7BuserId%7D/openrc#GET

API v3 documentation at https://docs.openstack.org/api-ref/identity/v3/index.html
To authenticate, the version 3 of API now requires to specify a \"domain\". Depending on your software, you might have to set only one domain, or one domain for the project and one domain for the user. The value is the same for both cases: the domain name is \"Default\". If your software requires an ID, the domain id is \"default\" (lowercase).

Note: The maintenance was originally planned on March 24, 2020 and got postponed due to the Covid-19 context.

Update(s):

Date: 2020-06-23 12:42:11 UTC
All requests made to Keystone API version 2 are now returning HTTP 410 Gone.

Date: 2020-06-23 12:13:16 UTC
The maintenance to shutdown Keystone API version 2 has started.

Date: 2020-06-05 14:42:05 UTC
Some Cloud Archive customers received a notification telling them that they were using Keystone API version 2.
This may be related to the use of Cloud Archive sftp/rsync/scp gateways.
No more notification about this usage will be sent. No action is required on customer side.

Date: 2020-05-05 12:05:07 UTC
The maintenance is now planned on June 23, 2020 at 12:00 UTC.
Communication notices will be sent in the next few days.

Date: 2020-03-16 11:29:26 UTC
This maintenance is postponed. A further notice will come to announce the new date for this change.
More information available at https://services.ovh.com/optiext/optiextension.dll?ID=A45A%2B1VbPpcWensb1h8ufMZlV4FitxCHio5fu2AkOWijz8ZQtbZYME1u9YFBgru1VSHi2KQvhJj0HtxvvNjiWHERwSoIS

Date: 2020-02-28 13:23:03 UTC
Some k8s customers received a notification telling them that they were using Keystone API version 2.
This may be related to some internal process run by k8s team. A patch is coming on their side.

Date: 2020-01-16 15:03:26 UTC
Please note that the payloads of request and response change in version 3 of the API.

Example with a token generation.

=== API v2 ===

Request body: https://storage.p19.cloud.ovh.net/v1/AUTH_47f7eb0153a7447799377451f59357ce/public/keystone-v2-request.txt

Response body (shortened): https://storage.p19.cloud.ovh.net/v1/AUTH_47f7eb0153a7447799377451f59357ce/public/keystone-v2-response.txt



=== API v3 ===

Request body: https://storage.p19.cloud.ovh.net/v1/AUTH_47f7eb0153a7447799377451f59357ce/public/keystone-v3-request.txt

Response body (shortened): https://storage.p19.cloud.ovh.net/v1/AUTH_47f7eb0153a7447799377451f59357ce/public/keystone-v3-response.txt
/!\\ Please note the token is now in the header X-Subject-Token /!\\
Posted Dec 23, 2019 - 18:02 UTC