Incident Report for Public Cloud

Resolved

Nous avons un incident sur le cluster ceph du GRA pour VPS. Nous investiguons sur le problème.

There are an issue on CEPH cluster on GRA for VPS cloud. Ceph team working on it.

Update(s):

Date: 2016-10-01 21:14:16 UTC
Si votre VPS est down, vous pouvez lancer le reboot.

--------------------EN version----------------

If your VPS is still down, please reboot it.

Date: 2016-10-01 21:12:54 UTC
UP !


Date: 2016-10-01 21:05:40 UTC
2) il y a beaucoup de lecture/écriture sur le cluster
ceph car les 5 PG sont UP. on n'arrive pas faire oublier
le dernier objet.

----------------------EN version--------------------------

2) we have lot of read/write on the ceph right now because
5 PG are UP now. the last one it's hard to make UP.

Date: 2016-10-01 20:55:45 UTC
2)
sous Ceph il existe une commande pour oublier un object.
elle a fonctionné pour 10 objects mais pas pour 7. pour
réussir à faire passer cette commande sur 7, on force
la commande d'effacement avec une commande \"while true\"
en boucle et pendant ce temps on essaie de redémarrer le
cluster en boucle aussi. les 2 boucles en même temps et
la magie fait qu'un moment ceph démarre en oubliant cet
objet.

il reste 1 PG fail. les 5 autres sont UP.

!!!!

----------------------EN version--------------------------

2)

in Ceph, there is a command to forget 1 objet. it's worked
on 10 objets but it doesn't on the others 7 objectss.
we've found out that if we run the command to forget the
objet with \"whie true\" loop and in the same time we run
the command to restart ceph in the \"while true\" loop too
after a while, ceph starts

the 5 PG of 6 are UP now. we still have the last objet
fail and 1 PG fail

!!!


Date: 2016-10-01 20:46:46 UTC
2) il nous reste 1 objet qui empêche Ceph de redémarrer.
le verdict dans quelques minutes.

en tout on perd 17 objects de 4Mo/8Mo chacun. donc environ
100Mo sur 120Tb. 0.08%

----------------------EN version--------------------------

2) we have only 1 objet that avoids to restart the Ceph.

we lose 17 objets with 4/8MB each. so 100MB/120TB. 0.8%

Date: 2016-10-01 20:09:30 UTC
On commence d'avoir quelques bons résultat sur la solution 2)

Sur la 4) on essaie d'identifier les VM lesquels on peut
restaurer.

----------------------EN version--------------------------

The solution 2) begins to work

4) We are trying to find out the VPS that are down to restore
the data.

Date: 2016-10-01 19:27:52 UTC
From War Room.

Bonsoir,
On recommande de ne pas rebooter votre VPS.

Le cluster Ceph impacté fonctionne sur 24 serveurs avec 12 disques
chacun. Nous avons un souci sur 6 hosts sur 24. C'est pourquoi toutes
les 5000 VPS ne sont pas down, car Ceph continue à fonctionner
sur les 18 serveurs restants. En tout, nous avons 6 Placement Group
(PG) en fail sur 10533 en tout sur le cluster. On essaie de faire
l'estimation le nombre de VPS réellement impactés car chaque donnée
est écrite sur beaucoup de PG.

Le probleme est suivant: nous avons 17 objects qui sont écrits
sur les disques dans la version 696135'83055746 et dans les
metadata de Ceph la version est 696135'83055747. Du coup Ceph
essaie de lire le fichier et dit que la version n'est pas bonne
puis s’arrête. Nous avons forcé Ceph à oublier ces fichiers,
mais ça ne fonctionne pas. Ceph se bloque car n'arrive pas à
ouvrir le PG (Placement Group).

On pense que le disque en défaut a flappé et Ceph a probablement
écrit le fichier en version 696135'83055747 sur ce disque et
n'a pas écrit les fichiers en version 696135'83055746 sur les
autres disques. Un probable bug dans la version qu'on fait
tourner en production 0.94.4. La dernière version est 0.94.9

On a un plan d'action en 4 points:

1) on va patcher l'outil d'import/export des objects pour lire
le fichier en version 696135'83055746 et forcer l’écriture en
version 696135'83055747. une équipe bosse dessus.

2) on regarde pourquoi Ceph se bloque quand on essaie de le
démarrer en forçant l'oublie de 17 objects. une autre équipe
bosse dessus.

3) dans le cas où tout ceci ne fonctionne pas, on va essayer
de démarrer le Ceph sans le 6 PG qui posent le probleme. Mais
les autres PG sur les 6 hosts seront UP.
cela veut dire qu'on va perdre quelques données. On ne sait pas
estimer qui serait impacté et qui ne serait pas, mais c'est
probable que le gros de VM vont revenir. Et les autres vont
probablement revenir avec FSCK dans la VM. Et peut-être on
aura quelques VM qui ne vont pas démarrer. C'est pourquoi on
vient de lancer un backup local sur chaque serveur de Ceph.
Il va prendre 6 heures environ.
Si jamais, je répète, si jamais on fait cette stratégie, on
va travailler sur les données du backup afin de récupérer
les données pour les éventuelles VM qui aurait perdu les
données. Mais quelques heures, quelques jours plus tard.
On espère qu'on n'aura pas à faire cette stratégie. une autre
équipe bosse sur cette stratégie. en cas où.

4) en parallèle, on a lancé la restauration de données pour
les VPS à partir de backup mais c'est hyper lent. On n'a pas
encore l'estimation de restauration. une autre équipe bosse
dessus.

Voilà le plan d'action en 4 points.

Amicalement
Octave

----------------------EN version--------------------------

From War Room.

Good evening
We recommand not to reboot your VPS.

The Ceph cluster is based on 24 servers. each with 12 disks. We have
the issue on 6 servers, not 24. That is why, not all 5000 VPS are down.
Some of them are down. The others continue to work with the remains
18 servers. We have an issue on 6 Placement Group (PG) and we have
10533 PG in this cluster. A small part of the data are fail but it can
impact lot of VPS. We are trying to estimate how many VPS are really
impacting, but it depends if 1) the VPS is using the 6 PG 2) the VPS wants
to read/write the data that are in the 6 PG.

The main issue is the version of the 17 objects. The objects are in the
version 696135'83055746. The version in the Ceph’s metadata is
696135'83055747. So Ceph doesn’t want to start. We’ve forced to
forget the bad files but it doesn’t work. Ceph is freezing.

We think that Ceph was trying to write the data on the failed disk.
Ceph has done it on the failed disk and updated the metadata, but
Ceph hasn’t done it on the others disks. Probably a bug in the version
we run 0.94.4. The last version is 0.94.9

4 action plans:

1)
we are patching the tool that can import/export the objects to force
the version of the object to 696135'83055747. 1 team is working on
this

2)
we are looking how to restart Ceph wihout 17 objects. an another
team is working on that.

3)
in the case, nothing works, we will start the Ceph without 6 PG, but
it means lost of some data. we don’t know which data would bel ost.
that is why we lauch a local backup of the data in the case we have
to work on it and restore the lost data in the futur. it’s a strategy
the « last case ». 1 team is working on that.

4)
we’are preapring the recovery of the data, but we are talking about
120TB. it will be slow, and the backup has 24 hours. 1 team is working
on that

Regards,
Octave

Date: 2016-10-01 16:12:22 UTC
Bonjour,
Nous avons un souci technique sur l'un de cluster CEPH.
Il s'agit d'un cluster de 200 disques de 2TB. L'ensemble
de données sont copiés 3x sur les disques et donc la
capacité totale du cluster est de 120To.

L'un de disques a été cassé et nous l'avons retiré. Pour
une raison on cherche encore, le cluster trouve qu'il
manque quelques données (17 objects) et se met en sécurité:
il s’arrête de fonctionner pour tous les données.

Les équipes travaillent sur le problème depuis ce matin
6h30. On a essayé beaucoup de choses depuis pour redémarrer
le cluster mais ça ne marche pas encore. Ca fait 11h30 que
certains devops sont sur le problème et donc on a décidé
de faire une pause d'1 heure et on recommence à bosser à 19h00.
On va commencer par faire un point entre toutes les équipes
qui bossent sur le souci Wroclaw (Pologne), Roubaix et Brest
au bureau par la telepresence. Le but est de voir si on a
raté quelque chose et regarder ce qu'on peut encore tenter.

Les données sont là. Il n'y a pas de raison qu'on ne trouve
pas comment remettre en marche le cluster.

Nous savons que l'impact est important. 5000 VPS utilise ce
stockage block qui est sensé fonctionner même quand ça ne
marche plus. On s’aperçoit que CEPH est très sensible et
en même temps ne réplique pas correctement les données. Il
est fort probable qu'on choisisse une autre technologie
dans l'avenir. Mais on n'en est pas là. Aujourd'hui, là
maintenant, ce qui compte c'est de remettre le cluster en
route.

Nous sommes sincèrement désolé pour cette longe panne.
Soyez rassuré sur une chose: on va bosser jusqu'à ce que
vos VPS soient UP. Malheureusement je ne peux pas encore
vous donner d'ETA car on n'a pas encore trouvé l'origine
du souci.

Amicalement
Octave

---------------------------EN version -------------------

Good evening,
We have a technical issue on 1 Ceph cluster. We have about 200
harddisk in this cluster. Each 2TB. We have 3 copy of each data
on 3 disks. This cluster manage 120To of data.

1 of the disks was broken and we removed it. For some reasons,
Ceph stopped to working : 17 objectfs are missed. It should not.

The teams has been working on the issue from 6 :30am. We’ve tried
lot of things to get it up. Some members of the team have 11 hours
uptime, that is why we’ve decided to stop working during 1 hour.
We will restart working at 7pm with a meeting between the team in
Wroclaw (Poland), Roubaix (France) and Brest (France). The goal
is to find out an action plan to resolv the issue.

We know the impact is important. About 5000 VPS are using this
Ceph cluster. The deal is simple : it has to work even if we lose 66.66%
of the hosts. Here we lost 1 hard disk and it’s broken. Once the data
are UP, we will write the post-mortem and see if we can find out an
another technology for the block storage. Right now, the goal is to
restore the data and we will.

We are very sorry about this long downtime. Be sure, we are working
on this issue and we will resolv this problem. I can’t give you right now
the ETA.

Regards,
Octave

Date: 2016-10-01 15:20:03 UTC
To summarize - we had 1 failing HDD. After removing OSD from it, 17 objects were unfound in Ceph after recovery. 7 of them are in 6 PGs which we cannot query or tell them to lose the objects. We have tried to manually force operations but did not succeed. We are still looking for a solution to unblock those PGs.

Date: 2016-10-01 14:56:16 UTC
We are still trying do debug what is locking the ceph cluster. Some hexadump has been done without succes for the moment.
In parallel we are trying to restore some backup

Date: 2016-10-01 11:13:10 UTC
Our team is still on it, the cluster is still lock, we are trying to unlock it.

Date: 2016-10-01 10:23:17 UTC
we lose one OSD, and for unknown reason all the cluster slow down. Ceph team working on it.

No ETA.

Date: 2016-10-01 08:47:11 UTC
because of a misbehaving storage node we experience degraded performance
Posted Oct 01, 2016 - 07:03 UTC